Quick Start Guide
2. To reduce sensor wiring length, mount the Rosemount 848T Wireless
transmitter central to all of the measurements. When installing the 848T
wireless, the conduit entries need to be facing downward. If using the
mounting bracket (Option Code B6), mount to a 2-in. pipe.
3. Run wiring (and conduit, if necessary) from the sensor to the 848T. For an
easier installation, use the outside conduit entries as shown below. Any
unused conduit entries should be sealed with approved sealant using the
included threaded conduit plugs.
A. Conduit Entry
B. Conduit Plug
4. Pull the wiring through the threaded conduit entry of the 848T.
5. Attach the sensor wiring to the terminals as indicated on the wiring diagram.
Note that Terminal screw 5 is for attaching the shield wire of the sensor to the
device. See 848T Wireless Reference Manual (Document No.
00809-0100-4848) for more information.